Аналитика Telegram-канала
Подписчики
559
Охват за 24 ч
95
ER за 24 ч
16,99%
Публикаций
100
Динамика подписчиков
7 дней
30 дней
6 месяцев
Больше
19 ноя22 ноя25 ноя
Показаны последние 7 дней
Больше истории →
Охваты публикаций
05.1105.1105.1115.1120.11
74
Средний охват
223
Лучший результат
Показаны 5 публикаций — последние в канале
Больше статистики →
Упоминания
5
Упоминаний
2
Из них репостов
4
Каналов
0
Упоминаний за 90 дней
0
Из них репостов
0
Каналов за 90 дней
Последние посты
3 из 100 2 из 100
A pair of Servosila-made large-size harmonic reducers sitting disassembled in a workshop.
These are Servosila PGK-41-100, harmonic reducers with a 100-to-1 reduction ratio.
#Kudos to STAN
ещё
54
0
5 20 ноя, 16:40
RC PWM Control Interface
All Servosila SC-series servo drives are equipped with an RC PWM input interface, which is compatible with most RC equipment, such as Futaba or Hitec. This interface enables the control of torque, speed, or position.
Additionally, the RC PWM interface can be used to trigger sophisticated motion sequences, such as a Starter-Generator start-up sequence demonstrated in the video.
The video illustrates the use of an RC servo tester to initiate a start-up sequence of a piston engine controlled by a Servosila SC-60R servo drive.
Although CAN, USB, MODBUS or EtherCAT interfaces of Servosila servo drives provide much more flexibility, the simplistic RC PWM interface is still a great choice in many applications.
#Kudos to V. Rutkoski
ещё
223
1
10 15 ноя, 14:07
MODBUS RTU (RS485) for Servosila Servo Drives
Introducing MODBUS control protocol support for Servosila SC-120R servo drives.
Key features include:
- Support for RS485 baudrates of up to 12 Mbit/s.
- A high-speed, low-latency motion control interface.
- The capability to chain multiple servo drives within a single RS485 network to control multiple degrees of freedom simultaneously.
- Internal unification of the MODBUS Register Map with the CANopen dictionary.
- Support for MODBUS Function Code 0x17 ("Simultaneous Write & Read") to minimize control and telemetry latency.
The RS485 control interface offers several distinct advantages over the CAN interface:
- Significantly higher baudrates are achievable, or, alternatively,
- Substantially longer cable lengths are permitted.
- A complete telemetry dataset is received in a single MODBUS packet, rather than being segmented into multiple shorter CANopen packets.
All SC-120R servo drives are now equipped with MODBUS RTU support as standard.
ещё
90
0
8 5 ноя, 16:14
Продолжить анализ этого канала
- История роста подписчиков
- Просмотры и охваты публикаций
- Кто упоминает канал и кого упоминает он
- Похожие каналы и подбор для рекламы
Открыть аналитику
Демо до 14 дней